GC112A Gas Liquid Chromatography Analysis Instrument 

Price: 100.0~3000.0 USD 
Payment Terms: T/T 
Place of Origin: Chongqing, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: GC112A
Production Capacity: 300 sets per month
Delivery Date: 10 working days
Means of Transport: Ocean,Air
Packing: Standard wooden case
Brand Name: Gold

GC112A Gas Liquid Chromatography Analysis Instrument
1.lifetime more than 5years
2.resonable price
3.factory

Introduction:

 

GC112A Gas Liquid  Chromatography Analysis Instrument is widely use for trace toxics analysis, monitoring and research in environmental protection, atmosphere and water source pollution;analysis, monitoring, research of toxicological; biochemistry; clinical application; pathology and virus research; food fermentation; Petroleum & Chemical; petroleum processing; oil analysis; geology, prospecting research; organic chemistry; synthesis; health and quarantine; analysis and research of public hazard detection .

 

 

Features:

 

1.     Brand-new designed microcomputer temperature control system of world advanced control technology. High accuracy of temperature control (optimum: ±0.05°C) high reliability and anti-interference.

2.     Control and operating parameters (including for detectors) set up by the keyboard. Self-diagnosis system, power-fail protection, file storage and call, limited temperature setting. Accurate display of setting and actual value of temperature control of each path, bridge current of TCD, sensitivity of FID, retention and analysis time.

3.     Four paths of independent control sections: column oven, sample injector, detector and thermal conductive pond.

4.     5-ramp programmed temperature rising control. Auto-drop of temperature of column oven (auto-opening the door behind the oven) to a fast cooling.

5.     Dual FID provided with options of GC112A-TCD, GC112A-ECD, GC112A-FPD and GC112A-NPD, gas sampling valve, transformation oven, absorber and pyrolysis absorber available for selection. Two detectors can be installed at the same time with high sensitivity. Short time to be stabilized and easy to clean and install nozzle.

6.     Packed column and capillary column (0.53 large diameter or small diameter) can be installed easily including a complete set of split sampling connector and tailing connector to be installed free of charge. Optional 0.53mm large diameter capillary direct sampler is available for choice.

7.     Analysis can be conducted in packed or capillary column with multiple sampling methods.

8.     Packed column: on-column sampling, instantaneous vaporized sampling and gas sampling.

9.     Capillary column: split sampling and 0.53mm large diameter capillary direct sampling.

10.   Construction of dual gas path, dual sample injector and dual packed column system can effectively avoid baseline undulation and drift in real time and facilitate programmed temperature rising analysis. Accurate and scaled type gas path control valves will provide a high repeatability and stability.

11.   Advanced functions: auto ON/OFF temperature control system, permanent data storage, file storage and call and over-temperature protection.

12.   Large volume column (300×280×270) can hold capillary column and dual packed column. Built-in heating filament structure is in favor of quartz capillary analysis.

13.   A complete set of accessories including purifier, pressure-reducing valve, gas path tube, wrench and tools, injection needle and connectors of all kinds are provided free of charge and are ready to connect with supply-air system prepared by user.

 

 

 

Specifications:

 1.Temperature Control

 

Control Range

7°C~400°C above room temperature. (increment of 1°C)

Control Objects

Column oven, detector, thermal conductive pond and sample injector

Programmed Temperature Rising

5 ramps

Rate of Programmed Temperature Rising

0.1°C~40°C (increment of 0.1°C)

Thermostatic Time

0~655min (increment of 1min)

 

 2.FID

 

Sensitivity (minimum testability)

M≤5×10-11g/s (sample: C16)

Optimum Testing Result         

M≤1×10-11g/s                                                            

Noise

≤5×10-14A

Drift

≤6×10-13A/h

Linear Range

≥106

 

 3.TCD

 

Sensitivity

≥2000mV·ml/mg

Noise

≤20μV                          

Drift

≤30μV

Linear Range

≥104

 

4.FPD

 

Sensitivity (maximum testability)

≤2×10-11g(P)/s (sample P in the parathion methyl)

Optimum testing result ≤3.8×10-12g(P)/s.

Sensitivity (maximum testability)

≤1×10-10g(S)/s (Sample S in the parathion methyl)

Optimum testing result ≤2.7×10-11g(S)/s.

Linear Range

≥103 (sample P parathion)

≥102 (sample S parathion)

Stability

≤30μV/h

Noise

≤10μV

Starting Time

Not greater than 2 hours

 

 5.NPD

 

Sensitivity (maximum testability)

Dt(N) ≤5pg(N)/s

Optimum testing result 0.5ppm

Sensitivity (maximum testability)

Dt(P) ≤0.5pg(P)/s

Optimum testing result 0.2ppm

Drift

≤8×10-13A/h                                                                

Noise

≤5×10-13A/h

Linear Range

≥103

Max Application Temperature

360°C

 

 Packing&Delivery

 

Payment & Shipping Terms

Supply Capacity

Payment term :

T/T or L/C

Production capacity :

500pcs/month

MOQ:

1 pc

Packing :

 Wooden case

Price

negotiable

Delivery way

 By Air

Means of transport :

FOB , CIF , CFR

Delivery time :

10 days

 

After-sales Service  

 

1. Warranty :one year

2.Engineers available to service machinery overseas

3.Provide free installation and debugging, staff training, technical guidance


bigPhoto
 Ms. Sunny

Tel: 86-23-62984892
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

Gold Mechanical & Electrical Equipment Co.,Ltd [China (Mainland)]


Business Type:Manufacturer
City: Chongqing
Province/State: Chongqing
Country/Region: China (Mainland)

You May Like:

Product (300)